Multisizer 4e Coulter Counter

The Multisizer 4e particle sizer and counter is the most accurate and flexible particle characterization device available, boasting an unparalleled sizing range of 0.2 - 1600 μm. The new 10 μm Aperture allows users to study sub-cellular and micro-particles as small as 200 nm, while the advanced noise reduction system for small apertures improves measurement accuracy.

Generated data are processed using patented digital pulse processing technology and can be saved and later re-analyzed. This technology provides ultra high resolution and accuracy unattainable through any other technologies: detection of 1 particle in 1 ml of a sample with the optimal instrument configuration. Analysis results are not dependent on particle shape, structure, or optical properties.

It uses the Coulter principle to detect particles via electrical zone sensing, regardless of the particle’s nature or optical properties. This makes it an ideal tool for detecting and counting a wide variety of particles, such as:

  • Mammalian cells
  • Bacteria
  • Yeast
  • Abrasives
  • Toner particles
  • Cell aggregates
  • Spheroids
  • Large protein aggregates

Additional Multisizer 4e Resources

Multisizer 4e Coulter Counter Features

Versatility

  • Aperture sizes from 10 µm - 2000 µm in diameter for current & future needs
  • Multiple aperture options & data overlay capability for analyzing complex samples over wide particle size distribution

Sample Detection

  • Analyze materials in aqueous or non-aqueous solvents
  • Ideal for biological or non-biological samples
  • Detect particles regardless of material type or optical properties

Rapid Particle Counting

  • Typical sampling rates up to 10,000 counts per second
  • Detect & count particles from 0.2 µm - 1600 µm in diameter
  • Sample volumes as small as 5 mL

Data Management

  • Digital pulse data can be stored & re-analyzed as needed
  • CFR 21 Part 11 compliant software for audit control & security
  • Variety of calibration beads & V-check validation controls

Explore Multisizer 4e Coulter Counter Models

Multisizer 4e Coulter Counter Specifications

Item Specifications Referenced A35595

Setting up a Multisizer 4e with an Accuvette

 

Content and Resources

Filter by:
Resource Type
インタビュー記事_iPS細胞由来ナチュラルキラー細胞の大量製造法開発におけるコールター原理の有用性 再生・細胞医療や遺伝子治療は、既存の医薬品では治療が難しい、あるいは治療法が確立されていない疾患に対して新たなモダリティとなる可能性があります。
アプリケーションノート_Multisizer 4eを用いたブロッキング防止パウダーの粒子径の品質管理 ブロッキング防止パウダーはプリント用紙、ラミネートフィルム用スリップ剤に用いられる粘着防止剤に使用されています。
アプリケーションノート_Multisizer 4e を用いた二枚貝の育成繁殖のための分析 「私たちは飼料として使用している水源中の藻類、細菌、懸濁した細粒堆積物が混じり合ったものの粒子数を測定しています。
アプリケーションノート_Multisizer 4eを用いたブロッキング防止パウダーの粒子径の品質管理 ブロッキング防止パウダーはプリント用紙、ラミネートフィルム用スリップ剤に用いられる粘着防止剤に使用されています。
製品カタログ_コールターカウンター Multisizer 4e 顕微鏡の発明以降、細胞計数の算定作業に膨大な時間が費やされてきました。

Technical Documents

Didn't find what you are looking for? For more results click here.