AQUIOS Tetra 試薬

迅速、高効率、ハイスループットなリンパ球サブセット解析

免疫不全疾患の臨床的なコントロールにおいて、白血球サブセットの絶対数を正確に測定し、血液中での個々のサブタイプの割合を知ることが重要です。AQUIOS 全自動クリニカルフローサイトメーターでAQUIOS Tetra試薬を使用することにより、カウントビーズなしで白血球サブセット解析が可能なシングルプラットフォームテクノロジー(SPT)を提供します。

AQUIOS Tetra Reagents

AQUIOS Tetra の特長

AQUIOS Tetra Reagents

AQUIOS Tetra-1 and AQUIOS Tetra-2+ are for In Vitro Diagnostic Use. AQUIOS CL with Tetra-1 has been accepted for the World Health Organization list of prequalified in vitro diagnostic products.

Barcoded Reagents

The AQUIOS reagents use a unique barcode identity for tracking reagent type, lot number, container number, expiration dates, and remaining reagent levels. The reagent consumption is monitored by the system as the samples are processed.

Comprehensive Quality Control

Barcode tracking eliminates the need for manual QC or reagent logs and generates a full, easily reviewable audit trail. Should QC fail, operator is alerted via text message or email.

Eliminate Steps with Every Sample

The AQUIOS CL System streamlines operations by incorporating automated loading, sample preparation, reagent management, and barcode scanning as well as data analysis and bidirectional LIS connectivity in one compact platform.

製品モデル

AQUIOS Tetra-1の仕様

Format Liquid
Specificity CD45, CD4, CD8, CD3
Form FITC, RD1, ECD, PC5
Clone B3821F4A / SFCI12T4D11 / SFCI21Thy2D3 / UCHT1
Isotype IgG2b Mouse / IgG1 Mouse
Target Species Human
Item Specifications Referenced B23533

関連資料

絞り込み:
 
London Health Sciences Centre (LHSC) Workflow Comparison Study with the Aquios CL Flow Cytometer The flow cytometry laboratory at Victoria Hospital is situated within a tertiary care academic institution, London Health Sciences Centre
University of Texas Medical Branch (UTMB) Workflow Comparison Study with the Aquios CL Flow Cytometer Many traditional flow cytometry systems, such as the current Becton Dickinson FACSCalibur™ with SPA II, require either manual or semi-automated preparation of samples, manual creation of worklists, manual data review, and manual tabulation of numerical data
AQUIOS CL Brochure AQUIOS CL Load & Go – And make flow cytometry simplicity itself
AQUIOS CL Brochure - Español AQUIOS CL Load & Go – Y haga que la citometría de fluja sea la simplecidad en sí misma
AQUIOS Tetra Application Gating Strategy The AQUIOS CL flow cytometer is intended for use as a Single Platform Technology (SPT) for lymphocyte subset analysis and enumeration

技術資料

Didn't find what you are looking for? For more results click の技術資料はこちらからご覧ください。