A Highly Consistent BCA Assay on Biomek i-Series
Summary
- BCA method automated on Biomek i-Series provides high consistency between replicates.
- Based on the desired throughput and walkaway, BCA method can be implemented on Biomek i5 Span-8, Biomek i5 Multichannel and Biomek i7 hybrid with Spectramax® i3 (Molecular devices).
The BCA (bicinchoninic acid) assay is a popular method used in quantification of proteins. The quantification is based on the purple color developed due to the chelation of copper ions by reduction bicinchoninic acid. The resulting complex absorbs at 562 nm and the optical density is proportional to the protein concentration in the sample. As BCA is not an end point method, the color continue to develop, even after the incubation. Therefore, equal time treatment of samples and replicates is crucial to eliminate the noise due to technical variation. This is difficult to achieve when the assay is carried out manually. Therefore, we automated the BCA assay on Biomek i-Series liquid handlers (Figures 1-2).

Figure 1. The workflow of BCA assay
Biomek i5 Span-8
- Ideal for medium- to high-throughput workflows
- Span-8 with 0.5- 5,000 μL pipetting capability
- Independent 360 degree rotating gripper with offset fingers for efficient and reliable labware movement
- 25 positions for increased walk away time
- Active ALPs for controlling sample processing – Orbital shakers, peltiers and tip wash

Biomek i5 Multichannel
- Ideal for medium- to high-throughput workflows
- Multichannel head in 96 or 384 format
- Independent 360 degree rotating gripper with offset fingers for efficient and reliable labware movement
- 25 positions for increased walk away time
- Active ALPs for controlling sample processing – Orbital shakers, peltiers and tip wash
Biomek i7 hybrid with integrations
- Ideal for high-throughput workflows
- 300 μL or 1,200 μL Multichannel head with 1-300 μL and 1-1,200 μL pipetting capability
- Span-8 pod with fixed and disposable tips
- Enhanced Selective Tip pipetting to transfer custom array of samples
- Independent 360 degree rotating gripper
- High deck capacity with 45 positions
- Orbital Shakers, peltiers span-8 and 96 channel Tip washing for controlling sample processing
- Integrated Spectramax® i3 (Molecular devices) to increase walkaway
Figure 2. Biomek i5 Span-8, Biomek i5 Multichannel and Biomek i7 hybrid with Spectramax® i3 (Molecular devices)
We purchased the Pierce™ BCA Protein assay kit (Thermo Scientific) with BSA standards. The method was automated separately on Biomek i5 Span-8, Biomek i5 Multichannel and Biomek i7 hybrid with Spectramax® i3 (Molecular devices).
Figures 3-5, shows the low CVs of the standards, indicating consistent sample preparation across triplicate wells (CV < 2.5%). The linearity (R2 > 97%) of the standard curve illustrate the consistent pipetting during serial dilution (Figures 3-5). Compared to manual processing, automation require less hands on time, as the Biomek carry out reagent preparation on-deck.

Figure 3 (A). Triplicate average absorbance and variability for BSA standards.
(B) Standard curve corresponding to Biomek i5 Span-8 automated BCA assay (R2 = 0.9787, error bars represent CV)..

Figure 4 (A). Triplicate average absorbance and variability for BSA standards. (B) Standard curve corresponding to Biomek i5 Multichannel automated BCA assay (R2 = 0.9861, error bars represent CV).

Figure 5 (A). Triplicate average absorbance and variability for BSA standards. (B) Standard curve corresponding to Biomek i7 hybrid automated BCA assay (R2 = 0.995, error bars represent CV).
BCA assay is a simple method that is easy to automate. Compared to manual processing, automation of the method provides the ability to improve the consistency of sample handling, especially when the throughput is high. For example, the 96 multichannel head of the Biomek can simultaneously process 96 samples at the same time, reducing the variability between replicates due to differential processing. The user can select the i-Series liquid handler based on the throughput and desired walkaway (Figure 2). For instance, integrating a reader to the Biomek provide end-to-end workflow automation and complete walkaway. In such situations, SAMI EX software ensures that each plate is treated the same way. This enables identification of biological variation, by lowering the technical noise.
References
1. Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., and Klenk, D. C. (1985) Measurement of protein using bicinchoninic acid. Analyt. Biochem. 150, 76–85.
2. Walker, J.M. (2002).The protein protocol handbook. Totowa, New Jersey: Humana Press Inc.
Helpful Links
-
資料集
-
アプリケーションノート
- 17-Marker, 18-Color Human Blood Phenotyping Made Easy with Flow Cytometry
- 21 CFR Part 11 Data Integrity for On-line WFI Instruments
- 8011+ Reporting Standards Feature and Synopsis
- Achieving Compliant Batch Release – Sterile Parenteral Quality Control
- 気中浮遊粒子のモニタリング:ISO21501-4校正のインパクト
- An Analytical Revolution: Introducing the Next Generation Optima AUC
- Analyzing Mussel/Mollusk Propagation using the Multisizer 4e Coulter Counter
- Automated 3D Cell Culture and Screening by Imaging and Flow Cytometry
- Automated Cell Plating and Growth Assays
- Automated Cell Transfection and Reporter Gene Assay
- Automated Cord Blood Cell Viability and Concentration Measurements Using the Vi‑CELL XR
- Automated Genomic Sample Prep-Ampure XP PCR
- Automated Genomic Sample Prep-RNAdvance
- Automated Genomic Sample Prep-Sample Quality Control
- Automated salt-assisted liquid-liquid extraction
- Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS
- Automated Transfection Methods
- Automated XTT Assay for Cell Viability Analysis
- Automating a Linear Density Gradient for Purification of a Protein:Ligand Complex
- Automating Biopharma Quality Control to Reduce Costs and Improve Data Integrity
- Automating Bradford Assays
- Automating Cell Line Development
- Automating Cell Line Development
- Automating Cell-Based Processes
- Automating the Cell Line Development Workflow
- The new Avanti J-15 Centrifuge Improves Sample Protection and Maximizes Sample Recovery
- The New Avanti J-15 Centrifuge Time Saving Deceleration Profile Improves Workflow Efficiency
- Avanti JXN Protein Purification Workflow
- Avoid the Pitfalls When Automating Cell Viability Counting for Biopharmaceutical Quality Control
- Beer, Evaluation of Final Product and Filtration Efficiency
- Biomek Automated Genomic Sample Prep Accelerates Research
- Biomek Automated NGS Solutions Accelerate Genomic Research
- 超遠心機および自動分注装置を用いた カーボンナノチューブの調製・精製と 分析用超遠心システムによる解析
- Cell Counting Performance of Vi–Cell BLU Cell Viability Analyzer
- Cell Line Development – Data Handling
- Cell Line Development – Hit Picking
- Cell Line Development – Limiting Dilution
- Cell Line Development – Selection and Enrichment
- Changes to GMP Force Cleanroom Re-Classifications
- Characterizing Insulin as a Biopharmaceutical Using Analytical Ultracentrifugation
- ハンドヘルド型気中パーティクルカウンターで行う クリーンキャビネットの定期的な評価
- Cleanroom Routine Environmental Monitoring – FDA Guidance on 21 CFR Part 11 Data Integrity
- Comparing Data Quality & Optical Resolution of the Next Generation Optima AUC to the Proven ProteomeLab on a Model Protein System
- Conducting the ISO 14644-3 Cleanroom Recovery Test with the MET ONE 3400
- Considerations of Cell Counting Analysis when using Different Types of Cells
- Consistent Cell Maintenance and Plating through Automation
- Control Standards and Method Recommendations for the LS 13 320 XR
- Counting Efficiency: MET ONE Air Particle Counters and Compliance to ISO-21501
- Critical Particle Size Distribution for Cement using Laser Diffraction
- CytoFLEX
- Detecting Moisture in Hydraulic Fluid, Oil and Fuels
- Determination of Size and Concentration of Particles in Oils
- Efficient kit-free nucleic acid isolation uses a combination of precipitation and centrifugation separation methods
- dsDNA Quantification with the Echo 525 Liquid Handler for Miniaturized Reaction Volumes, Reduced Sample Input, and Cost Savings
- Compensation Setup For High Content DURAClone Reagents
- Echo System-Enhanced SMART-Seq v2 for RNA Sequencing
- Efficient Factorial Optimization of Transfection Conditions
- Enhancing Vaccine Development and Production
- Enumeration And Size Distribution Of Yeast Cells In The Brewing Industry
- European Pharmacopoeia EP 2.2.44 and Total Organic Carbon
- Evaluation of Instrument to Instrument Performance of the Vi-CELL BLU Cell Viability Analyzer
- Exosome-Depleted FBS Using Beckman Coulter Centrifugation: The cost-effective, Consistent choice
- Flexible ELISA automation with the Biomek i5 Workstation
- Full Automation of the SISCAPA® Workflow using a Biomek NXP Laboratory Automation Workstation
- Fully-Automated Cellular Analysis by Flow Cytometry
- Get Control in GMP Environments
- g-Max: Added Capabilities to Beckman Coulter's versatile Ultracentrifuge Line
- 遠心機によるナノセルロースの分級
- 超遠心法によりナノ粒子を分級して 正確な粒子径を求める方法
- 超遠心分離法 / 動的光散乱法による 顔料インクの分級と粒子径測定
- HIAC Industrial – Our overview solution for fluid power testing for all applications
- HIAC PODS+ Online Mode & Filter Cart Mode
- HIAC PODS+ versus Parker ACM-20 Performance comparison
- A complete workflow for high-throughput isolation of DNA and RNA from FFPE samples using Formapure XL Total on the KingFisher™ Sample Purification System: an application for robust and scalable cancer research and biomarker discovery
- A Highly Consistent BCA Assay on Biomek i-Series
- A Highly Consistent Bradford Assay on Biomek i-Series
- A Highly Consistent Lowry Method on Biomek i-Series
- Highly Reproducible Automated Proteomics Sample Preparation on Biomek i-Series
- Cell Line Development – Hit Picking
- How to Use Violet Laser Side Scatter Detect Nanoparticle
- How Violet Side Scatter Enables Nanoparticle Detection
- HIAC(ハイアック)システムでHRLDセンサーを使用する際の推奨ターボリューム設定
- 油中パーティクルカウンターのサンプル調製 繰返し精度を維持するための最善の方法
- ICH Q2 – the Challenge of Measuring Total Organic Carbon in Modern Pharmaceutical Water Systems
- ICH Q2 – The Challenge of Measuring Total Organic Carbon in Modern Pharmaceutical Water Systems
- Importance of TOC measurement in WFI in light of European Pharmacopoeia change
- Temperature dependence of hydrodynamic radius of an intrinsically disordered protein measured in the Optima AUC analytical ultracentrifuge.
- Isolation of cell-free DNA (cfDNA) from plasma using Apostle MiniMax™ High Efficiency cfDNA Isolation kit— comparison of fully automated, semi-automated and manual workflow processing
- Issues with Testing Jet Fuels for Contamination
- Leveraging the Vi-CELL MetaFLEX for Monitoring Cell Metabolic Activity
- Linearity of BSA Using Absorbance & Interference Optics
- 光学式パーティクルカウンターにおける「Long Life Lasers(長寿命レーザー)」の検証
- LS 13 320 XR: Sample Preparation - How to measure success
- Particle Size Analysis Simple, Effective and Precise
- Matching Cell Counts between Vi–CELL XR and Vi–CELL BLU
- MET ONE センサーの過酸化水素ガス(VHP)耐性
- 超遠心分離法による 金属コロイド精製と濃縮
- 密度勾配遠心法による 金ナノロッドの分離精製
- Method for Determining Cell Type Parameter Adjustment to Match Legacy Vi CELL XR
- Minimal Sample to Sample Carry Over with the HIAC 8011+
- ミネラルウォーター製造工程のばらつき最小化
- Modern Trends in Non‐Viable Particle Monitoring during Aseptic Processing
- Multi-Wavelength Analytical Ultracentrifugation of Human Serum Albumin complexed with Porphyrin
- ナノ粒子複合材の粒子径測定 - 密度勾配超遠心法と動的光散乱法を用いて -
- What to do now that ACFTD is discontinued
- Optimizing the HIAC 8011+ Particle Counter for Analyzing Viscous Fluids
- Optimizing the Multisizer 4e Coutler Counter for use with Small Apertures
- Optimizing Workflow Efficiency of Cleanroom Routine Environmental Monitoring
- Particle Counting in Mining Applications
- パーティクルカウンター資料集 高圧ガス配管内の清浄度測定- MET ONE 3400ガス校正オプションで ISO 14644の計測を簡単に -
- 無菌医薬品製造区域の環境モニタリング
- 無菌医薬品製造のためのペーパーレスによる環境モニタリング
- Principles of Continuous Flow Centrifugation
- Protein purification workflow
- Background Subtraction
- Calibrating the QbD1200 TOC Analyzer
- Detection Limit
- Inorganic Carbon Removal
- JP SDBS Validation
- Method Overview
- Overload Recovery
- QbD1200 Preparing Reagent Solution
- USP System Suitability
- Quality Control Electronic Records for 21 CFR part 11 Compliance
- Using the Coulter Principle to Quantify Particles in an Electrolytic Solution for Copper Acid Plating
- RCC A standardized automated approach for exosome isolation and characterization
- RCC Avanti J 15 Series Maximizing Sample Protection and Sample Recovery
- RCC Avanti J 15 Series Time Savings and Workflow Efficiency
- Root Cause Investigations for Pharmaceutical Water Systems
- Scalable Plasmid Purification using CosMCPrep
- Specification Comparison of Vi–CELL XR and Vi–CELL BLU
- Specifying Non-Viable Particle Monitoring for Aseptic Processing
- A Standardized, Automated Approach For Exosome Isolation And Characterization Using Beckman Coulter Instrumentation
- Switching from Oil Testing to Water and back using the HIAC 8011+ and HIAC PODS+
- Advanced analysis of human T cell subsets on the CytoFLEX flow cytometer using a 13 color tube-based DURAClone dry reagent
- Using k-Factor to Compare Rotor Efficiency
- 新規格 USP HIAC System 9703+における 少容量サンプルテストへの適用
- Validation of On-line Total Organic Carbon Analysers for Release Testing Using ICH Q2
- Vaporized Hydrogen Peroxide Decontamination of Vi–CELL BLU Instrument
- Vi CELL BLU FAST Mode Option
- Vi-CELL BLU Regulatory Compliance - 21 CFR Part 11
- A workflow for medium-throughput isolation of cfDNA from plasma samples using Apostle MiniMax™ on the KingFisher™ Technology
- 製品カタログ / データシート
- 総合カタログ
- フライヤー
-
ポスター
- Applications of Ultracentrifugation in Purification and Characterization of Biomolecules
- Automating Genomic DNA Extraction from Whole Blood and Serum with GenFind V3 on the Biomek i7 Hybrid Genomic Workstation
- ABRF 2019: Automated Genomic DNA Extraction from Large Volume Whole Blood
- AACR 2019: Isolation and Separation of DNA and RNA from a Single Tissue or Cell Culture Sample
- AACR 2019: Correlation between Mutations Found in FFPE Tumor Tissue and Paired cfDNA Samples
- AGBT 2019: A Scalable and Automatable Method for the Extraction of cfDNA
- ABRF 2019: Simultaneous DNA and RNA Extraction from Formalin-Fixed Paraffin Embedded (FFPE) Tissue
- AMP 2019: Correlation Between Mutations Found in FFPE Tumor Tissue and Paired cfDNA Samples
- Automated library preparation for the MCI Advantage Cancer Panel at Miami Cancer Institute utilizing the Beckman Coulter Biomek i5 Span-8 NGS Workstation
- Automating Cell Line Development for Biologics
- Cellular Challenges: Taking an Aim at Cancer
- Cell-Line Engineering
- Characterizing the Light-Scatter Sensitivity of the CytoFLEX Flow Cytometer
- ASHG 2019: Comparison between Mutation Profiles of Paired Whole Blood and cfDNA Samples
- ASHG 2019: Correlation Between Mutations Found in FFPE Tumor Tissue and Paired cfDNA Samples
- Mastering Cell Counting
- Preparing a CytoFLEX for Nanoscale Flow Cytometry
- A Prototype CytoFLEX for High-Sensitivity, Multiparametric Nanoparticle Analysis
- 製品の取扱説明書
- プロトコル
-
導入事例
- 高速冷却遠心機を用いたアデノウイルスベクターの効率的で再現性の良い調製方法
- セルソーターを用いたバイオ燃料高産生藻のハイスループット遺伝子改変オートメーションシステム
- 「細胞のごみ」を分解するオートファジーの 全容に迫る
- B細胞の生成と成熟、維持の研究を創薬にも活かす
- 動脈硬化の免疫的な機序から心血管疾患の治療と予後を研究 ― マルチカラーフローサイトメーターで研究を加速 ―
- 10カラーフローサイトメトリーを用いた細胞マーカー解析の有用性
- 研究に最適な卓上遠心機を選択するポイント
- 新しいアプローチでの膠原病疾患治療に向けて
- 機能性抗体で免疫応答を制御し、新しい治療戦略と創薬に結びつける ― 研究を加速するフローサイトメーター ―
- 炎症の観点から疾患の発症メカニズムを解明し、治療薬を創出する
- がん遺伝子パネル解析/クリニカルシーケンスにおけるFFPE組織切片からのゲノムDNA抽出の重要性
- 大学における留学生を対象とした英語による遠心機の安全教育セミナーの有用性
- 大学における共通機器室の機器管理とサポート体制について
- 超遠心法を用いたエクソソームの分離精製
- 免疫研究で漁業の未来を変える - 研究の効率を上げるフローサイトメーター -
- 高精度の迅速診断に向けて - Navios EXによる造血器腫瘍細胞の10カラー解析の導入 -
- iPS 細胞のメカニズムと 安全で効率のよい 樹立・維持法を追究
- X線結晶構造解析のための膜タンパク質精製の基礎
- 密度勾配超遠心法による簡便な細胞小器官の分画
- 粒子間の相互作用研究から、細胞と粒子の相互作用研究へ
- 虹彩細胞からの網膜細胞再生へ ~MoFlo Astriosの役割~
- 堆積地質学の研究における粒度分布測定
- iPS 細胞由来の “ 肝臓の芽 ” の移植で重度肝疾患の治療を目指す
- 患者の自己骨髄細胞を用いて肝硬変を治療する
- 大学の共通機器室での機器管理とサポート体制について
- 超遠心法によるウイルス精製の基礎
-
ホワイトペーパー
- Centrifugation is a complete workflow solution for protein purification and protein aggregation quantification
- AUC Insights - Analysis of Protein-Protein-Interactions by Analytical Ultracentrifugation
- AUC Insights - Assessing the quality of adeno-associated virus gene therapy vectors by sedimentation velocity analysis
- AUC Insights - Sample concentration in the Analytical Ultracentrifuge AUC and the relevance of AUC data for the mass of complexes, aggregation content and association constants
- Hydraulic Particle Counter Sample Preparation
- eBook
- インタビュー記事
-
アプリケーションノート
お問い合わせ